Power Adaptors
1AC input range: 100-240V.
2 Class I I power supply with two-pole AC plug
3 Protection: short circuit / overload
4 Fully protected plastic case LED indicator on the front shell to show the working condition.
5100% full burn-in test: full load burn-in test at low voltage AC110V, no-load burn-in test at high
4 Voltage AC265V and repeated switch of AC power at high voltage AC265V. Through LPS (limited power source)
5Operating altitude is up to 5000 meters (note 8).
5High efficiency, long service life, high reliability.
1 . All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2 . Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3 . Tolerance: includes set up tolerance, line regulation and load regulation.
4 . Line regulation is measured from low line to high line at rated load.
5 . Load regulation is measured from 0% to 100% rated load.
6 . Set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
7 . When the peak load of the unit reaches 150% and delivers for over 1 second, it enters hiccup mode and recovers once rated current lower than 150%.
8 . The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500G).
MODEL |
FS-12D2000-B |
|
Output |
DC VOLTAGE |
12V |
RATED CURRENT |
2A |
|
CURRENT RANGE |
0-2A |
|
RATED POWER |
24W |
|
VOLTAGE TOLERANCE(Note4) |
±5.0% |
|
LINE REGULATION(Note3) |
±0.5% |
|
LOAD REGULATION(Note5) |
±1% |
|
RIPPLE&NOISE(Note2) |
≤100mVp-p |
|
SETUP, RISE TIME |
1300ms,40ms/230VAC 2200ms, 16ms/115VAC(at full load) |
|
INPUT |
VOLTAGE RANGE |
96-264V |
AC CURRENT (Typ.)
|
0.5A/115VAC |
|
FREQUENCY RANGE |
47-63Hz |
|
EFFICIENCY (Typ.) |
84% |
|
LEAKAGE CURRENT |
<2mA/ 240VAC |
|
INRUSH CURRENT (Typ.) |
20A/115VAC |
|
30A/230VAC |
||
PROTECTION |
OVERLOAD(Note.7) |
110 ~ 140% rated output power |
Protection type: Hiccup mode, recovers automatically after fault condition is removed |
||
ENVIRONMENT |
WORKING TEMP. |
-25-70℃(Refer to "Derating Curve") |
WORKING HUMIDITY |
20%-90% RH non-condensing |
|
STORAGE TEMP, HUMIDITY |
-40-85℃ 10%---95% RH |
|
TEMP. COEFFICIENT |
± 0.03%/ 50℃ (0 ~ 50℃) |
|
VIBRATION |
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes |
|
SAFETY |
SAFETY STANDARDS |
IEC/EN/UL/CSA 60950 GB4943 |
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC, I/P-FG:2KVAC, O/P-FG0.5KVAC |
|
EMC EMISSION |
Compliance to BSMI CNS13438, EAC TP TC 020 |
|
EMC IMMUNITY |
Compliance to EAC TPTC 020 |
|
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃ / 70% RH |
|
OTHERS |
MTBF |
≥327.9K hrs min. MIL-HDBK-217F(25℃) |
DIMENSION (L*W*H mm) |
99*48*31.4mm (L*W*H) |
|
PACKING |
100pcs/21.7Kg/0.065CUFT |
|
PRODUCT WEIGHT |
0.2KGS |